A regulator or flowmeter is a small part of your setup, but the wrong one can waste gas, cause porous welds or, with oxy-acetylene, be dangerous. This guide explains what each one does and how to set it up safely.
Regulator, flowmeter or flow gauge?
- Regulator: reduces the high pressure in the cylinder to a safe working pressure. Oxy-acetylene, LPG and other fuel gas equipment uses regulators set in kilopascals.
- Flowmeter: used for MIG and TIG shielding gas. A ball rises in a clear tube and you read the flow in litres per minute at the top of the ball. The Canadian Welding Bureau explains that flowmeters are calibrated for one gas at a set inlet pressure.
- Flow gauge: looks like a regulator with a second dial marked in litres per minute. It sets flow by changing pressure through a fixed opening. It is also calibrated for one gas, so read the scale for the gas you are using.
Match the regulator to the gas
Every regulator, hose and fitting is made for a particular gas, and Australian cylinder valves have different connections for different gases to stop mix-ups. Never adapt a regulator to fit a different cylinder. Oxygen equipment must be kept completely free of oil and grease: BOC warns that high pressure oxygen will react violently with oils and grease.
Single stage or two stage?
A single stage regulator is fine for occasional use, but its delivery pressure can creep as the cylinder empties. A two stage regulator drops the pressure in two steps and holds a steady output for the life of the cylinder, which suits production work and TIG welding.
Starting flow rates for MIG and TIG
Air Products, a major gas supplier, suggests about 8 to 12 L/min for argon based gases on thin material (1 to 3 mm) and about 15 to 20 L/min on thicker material. Use these as starting points:
| Process | Typical starting flow |
|---|---|
| MIG on mild steel | 10 to 15 L/min |
| MIG on aluminium (pure argon) | 15 to 20 L/min |
| TIG on steel and stainless | 8 to 12 L/min |
| TIG on aluminium | 10 to 15 L/min |
More is not better. Too much flow wastes gas and can pull air into the weld through turbulence. If you get porosity, check for draughts, leaks and a blocked nozzle before turning the gas up.
Oxy-acetylene safety
- Fit flashback arrestors at both ends. WorkSafe ACT, citing AS 4839, recommends flashback arrestors at both the regulator end and the torch end of the oxygen and fuel gas lines. They must suit the gas, comply with AS 4603 and be inspected and tested every 12 months.
- Keep acetylene pressure low. Acetylene becomes unstable at higher pressures, so keep the delivery pressure at or below about 100 kPa (15 psi).
- Open cylinder valves slowly and only once the regulator is fitted, as BOC advises.
- Store cylinders upright and restrained. BOC says acetylene and LPG cylinders must never be stored lying down.
- Check hoses and fittings for leaks with a suitable leak detection solution, never a flame.
Shop the range
Browse gas equipment for regulators and flowmeters, flashback arrestors, hoses, torches, tips and complete gas kits.
Not sure what you need? Call the Electroweld team in Greenacre on (02) 9708 6660 or bring the job (or a photo of it) into the shop.
Sources: Canadian Welding Bureau (flowmeters and flow gauges); Air Products (controlling gas flow rates); WorkSafe ACT (flashback arrestors, AS 4839 and AS 4603); BOC Guidelines for Gas Cylinder Safety.