Description
- Designed for connection to the outlet of regulators incorporating a pressure actuated cut-off valve to prevent further gas flow after a flashback occurs.
- Pressure actuated cut-off valve to prevent further gas flow after a flashback occurs. The operation is indicated by a signal level. After resetting the lever it is ready for immediate re-use.
- Resettable lever enables the user to quickly and seafely resume work after addressing the cause of the flashback or reverse gas flow. This feature allows for efficient and uninterrupted operation.
- Non-return valve.
- Large surface stainless steel conical flame arrestor.
- Pressure relief valve to vent excessive pressure.
- Temperature activated shut-off valve.
- Supplied with an inlet filter.
- Complies to AS4603.
- Conforms to EN730/DIN 8521, UL, ISO 5175 class I (fittings to AS4267-1995).
- Tested by BAM.
Specifications
| Gas Type | Oxygen |
|---|---|
| Reset Type | RESETTABLE |
| Part number | 308799M |
Good to know: flashback arrestors and oxy-fuel safety
A flashback is when the flame or burning gas mixture travels back up the torch and hoses towards the regulators and cylinders. Flashback arrestors stop it. Most combine a non-return valve, a flame arrestor and a thermal cut-off that closes if the unit gets too hot.
- Australian guidance (AS 4839) is to fit arrestors at both the regulator and the torch, on the oxygen and the fuel gas lines.
- Arrestors should comply with AS 4603 and suit your gas and equipment.
- Have arrestors inspected and tested by a competent person every 12 months.